BRHSG - VITON FLUOROELASTOMER, VITON A

Product Identification

Product ID:VITON FLUOROELASTOMER, VITON A
MSDS Date:09/17/1990
FSC:6850
NIIN:00N038978
MSDS Number: BRHSG

Responsible Party
E I DU PONT DE NEMOURS & CO INC
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515;302-773-6587

Preparer: W.H. MARTIN

Cage: B0589

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

FLUORINATED SYNTHETIC RUBBER; (VINYLIDENE

CAS: 9011-17-0

Fraction By Weight: >99%

OSHA PEL N/K

ACGIH TLV: N/K


BARIUM SULFATE

CAS: 7727-43-7

RTECS: CR0600000

Fraction By Weight: <10%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:NOT A PROBABLE ROUTE OF
EXPOSURE. LOW TOXICITY. SKIN:PROLONGED CONTACT MAY PRODUCT SKIN
IRRITATION. AVOID SKIN CONTACT. EYE:MECHANICAL IRRITATION.
INHAL:TOX & CORROSIVE HYDROGEN FLUORIDE MAY BE LIBERATED DURING
PROCESSING >200C, OR FROM SMOKING TOBACCO OR CIGARETTES
CONTAMINATED WITH RESIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DUST. THESE VAPORS CAN IRRITATE THE
EYS, NOSE, THROAT, AND LUNGS. LUNG EFFECTS MAY BE DELAYED FOR
SEVERAL HOURS. CHRONIC:NONE KNOWN. IF "VITON" IS USED AT TEMPS
>316C (600F), THE SURF OF PART S MAY CNTN HF OR HF CONDENSATE,
WHICH MAY CAUSE SEVERE BURNS, SOMETIMES W/SYMPS DELAYED FOR SEV
HOURS.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INHAL:IF EXPOSED TO FUMES FROM OVERHEATING OR COMBUSTION,
MOVE TO FRESH AIR. CALL MD IF SYMPTOMS PERSIST. SKIN:CLEANSING THE
SKIN AFTER USE IS ADVISABLE. IF MOLTEN POLYMER GETS ON SKIN, COOL
RAPIDLY W /COLD WATER. DO NOT ATTEMPT TO PEEL POLYMER FROM SKIN.
GET MD FOR THERMAL BURN. EYE:FLUSH W/PLENTY OF WATER FOR AT LEAST
15 MINS. GET MD IF SYMPS PERSIST. INGEST:CALL MD IF NECESSARY.

Fire Fighting

Flash Point Method:OC
Flash Point:>399F,>204C
Extinguishing Media:WATER, FOAM, DRY CHEMICAL, CO*2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . DOES NOT BURN WITH OUT EXTERNAL FLAME.
Unusual Fire/Explosion Hazard:PELLET FORM MAY ACCUMULATE STATIC CHARGE
WHEN POURED FROM ONE CNTNR TO ANOTHER. HAZ GASES/VAPS PRODUCED IN
FIRE:HYDROGEN FLUORIDE, CARBONYL FLUORIDE, (SUPDAT)

Accidental Release

Spill Release Procedures:REVIEW FIRE & EXPLOSION HAZARDS & SAFETY
PRECAUTIONS BEFORE PROCEEDING WITH CLEAN UP. USE APPROPRIATE
PERSONAL PROTECTIVE EQUIPMENT DURING CLEAN UP. SWEEP UP TO PREVENT
SLIPPING HAZARDS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE. KEEP
CONTAINERS TIGHTLY CLOSED TO PREVENT MOISTURE ABSORPTION AND
CONTAMINATION.
Other Precautions:PROVIDE GROUNDING OF EQUIPMENT WHILE HANDLING PELLET
FORM TO PREVENT STATIC BUILD-UP. AVOID CONTAMINATION OF CIGARETTES
OR TOBACCO WITH POLYMER. DO NOT TOUCH DECOMPOSED PARTS OF "VITON"
EVEN WHEN COOL .

Exposure Controls

Respiratory Protection:NOT REQUIRED IF LOCAL VENTILATION IS ADEQUATE.
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:VAPS & FUMES LIBERATED DURING HOT PROCESSING SHOULD BE
EXHAUSTED FROM WORK AREAS TO MAINTAIN HYDROGEN FLUORIDE (SUPDATA)
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IF "VITON" IS USED @ >316C, WEAR
NEOPRENE/PVC (IF TEMP IS LOW ENOUGH) GLOVES WHEN HNLDG PARTS OR
EQUIP AFTER (SUPDAT)
Work Hygienic Practices:IF HF CONDENSATE IS EXPECTED, WASH EQUIPMENT
PARTS WELL WITH LIMEWATER (CALCIUM HYDROXIDE SOLUTION). DISCARD
GLOVES.
Supplemental Safety and Health
CNDTNS TO AVOID:"HANDLING PRECAUTIONS FOR "VITON" & ITS RELATED
CHEMICALS". EXPLO HAZ:CARBON MONOXIDE AND LOW MOLECULAR WEIGHT
FLUOROCARBONS. VENT:CONCENTRATION BELOW OSHA PEL OF 3 PPM. OTHER
PROT EQU IP:EXPOSURE TO SUCH HIGH TEMPERATURES.

Chemical Properties

Spec Gravity:1.77-1.86
Solubility in Water:INSOLUBLE
Appearance and Odor:ODORLESS PELLETS, CHIPS OR SHEETS

Stability

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH FINELY DIVIDED METALS SUCH AS ALUMINUM. COMPOUNDING
WITH METAL POWDERS PRESENT AN EXPLOSION HAZARD.
Stability Condition to Avoid:TEMPS >200C (>392F) W/OUT ADEQ VENT WHEN
COMPOUNDING INGREDS ARE PRESENT. SEE BULLETIN VT-100.1 (4/87) (SUPP
DATA)
Hazardous Decomposition Products:HYDROGEN FLUORIDE & PERFLUOROOLEFINS.

Disposal

Waste Disposal Methods:PREFERRED OPTIONS FOR DISP ARE 1:RECYCLING &
2:LANDFILL. INCIN ONLY IF INCIN IS CAPABLE OF SCRUBBING OUT
HYDROGEN FLUORIDE & OTHER ACIDIC COMBUST PRODS. TREATMENT, STORAGE,
TRANSPORTATION, & DISP MUST BE I/A/W APPLIC FED, STATE, & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.